Rental Equipment

 

Flushing Skids :

The rental units are designed to provide flushing and filtration for both new and existing hydraulic systems. Designed by HyPower Systems, the 4200, 6100, and 6130 series are capable of full forward and reverse flow over a wide range of pressures. The unloading circuit design allows excessive flow from the pump to be diverted to tank, which reduces wasted power and heat build-up during idle periods.  Filtration is provided via the Pall in-tank return filter and high-pressure filter assemblies.

SPECIFICATIONS

4200 Series

Reservoir - 120 U.S. Gallon – High Stack.
Pump - Vickers Double Vane Pump 63 gpm at 600 psi and 17 gpm at 2400 psi.
Optimum Oil Viscosity - 16 cSt (80 SUS) – 40 cSt (180 SUS) *
Electrical Motor - 30 hp, 1800 rpm, TEFC industrial motor.
Required Power Supply - Dual Selectable Voltage 460 v / 575 v / 3 ph / 60 Hz.
Pressure Filter - Pall UH319 SRT series ‘AN’ element : 7 μm rating – 15/11/04.
Return Filter - Pall UT319 SRT series ‘AN’ element : 7 μm rating – 15/11/04.
Dimensions - 30” W x 75” L x 75” H.
Approximate Dry Weight - 1200 lbs.

6100 Series

Reservoir - 150 U.S. Gallon – JIC
Pump - Vickers Double Vane Pump 103 gpm at 600 psi / 38 gpm at 1250 psi
Optimum Oil Viscosity - 16 cSt (80 SUS) – 40 cSt (180 SUS) *
Electrical Motor - 40 hp, 1800 rpm, TEFC industrial motor.
Required Power Supply - Dual Selectable Voltage 460 v / 575 v / 3 ph / 60 Hz.
Pressure Filter - Pall 9660 series ‘KN’ element : 7 μm rating – 15/11/04.
Return Filter - Pall UT319 SRT series ‘AN’ element : 7 μm rating – 15/11/04.
Dimensions - 42” W x 78” L x 84” H.
Approximate Dry Weight - 1600 lbs.

6130 Series

Reservoir - 150 U.S. Gallon – JIC.
Pump - Vickers Double Vane Pump 75 gpm at 500 psi / 45 gpm at 1250 psi.
Optimum Oil Viscosity - 16 cSt (80 SUS) – 40 cSt (180 SUS) *.
Electrical Motor - 40 hp, 1800 rpm, TEFC industrial motor.
Required Power Supply - Voltage 575 v / 3 ph / 60 Hz.
Pressure Filter - Pall HC9600 series ‘KN’ element : 7 μm rating – 15/11/04.
Return Filter - Pall HC9700 series ‘KN’ element : 7 μm rating – 15/11/04.
Dimensions - 42” W x 72” L x 76” H.
Approximate Dry Weight - 1500 lbs.

Purifiers:

HyPOWER Systems employs quantity-2 Pall portable fluid purifiers. The HNP021 and the HVP-903. These purifiers will condition hydraulic fluid and lubrication fluid by removing water, solid particulate contamination, air, and gases from high and low viscosity lubrication fluid, hydraulic fluid, and insulating oils.

The water removal principle used is simple and reliable, and will dependably remove water to well below the saturation point even under the adverse condition of 100% relative humidity ambient air.

The HNP and HVP series oil purifiers reduce system wear; improve on-line and system performance; extend fluid life; and reduce fluid disposal costs and
environmental risks.

The HNP and HVP series Purifiers are a fluid purification system designed to remove the following:

  • Water ......100% of free water and as much as 90% of dissolved water,
    depending upon running vacuum setting.
  • Gases .....100% of free and entrained gases and in excess of 80% of
    dissolved gases, depending upon running vacuum setting.
  • Dirt..........including silt and other solids or particulate contaminant.
  • HNP021 Series – for usage on reservoirs of 100 to 800 gallons.
  • HVP903 Series – for usage on reservoirs of 800 to 6000 gallons.

HyPOWER Oil Transfer Carts : Stock item for purchases only.  Cost effective, these units are portable, easy to use and sets up in minutes.

Recommended for new or existing hydraulic systems. Ensures new oil added to the system is properly filtered. Capable of
9 GPM of flow and can be used for the transfer and filtration of lube oils up to and including ISO320 fluids based on 20 °.

| back | ahead |







| Eaton Repair & Warranty | Manufacturing | Mobile Service | Rental Equipment | Repair & Testing |
 

copyright (2009) HyPOWER Systems       web design by CanadaWeb Inc.